AHP - AIR DRIVEN HYDROTEST PUMPS - STANDARD FLOW
|
- Output pressures from 6 to 2931 Bar
- Suitable for use with various fluids.
- 150 mm dual scale vibra pressure gauge
|
» Air consumption 28 scfm (0,79m3/minute)
» Infinitely variable output pressure and flow |
The Hi-Force AHP series of lubricant free air driven hydrostatic pressure testing pumps offers a choice of eight models with output pressure capacities ranging from 69 Bar (1000 PSI) to 2933 Bar (42500 PSI). All models are suitable for use with various fluids, including water and are supplied with a 150mm diameter hydraulic pressure gauge (calibrated on request), inlet airline filter & pressure regulator unit, lightweight fluid reservoir, pump start/stop valve and a robust stainless steel skid mounted framework. Optional extras available also include stainless steel fluid reservoirs, stroke counter plunger assembly with IP65 microswitch & digital impulse counter, pressure isolation valve and onboard circular chart recorders. All units are of compact design with a maximum weight of 23 kg.
Model
number |
Max. output pressure (bar) at airline input pressure |
Oil volume
displacement
per stroke (cm3) |
Outlet port
thread |
Weight
kg |
|
Dimensions in mm |
10 PSI
0.69 Bar |
50 PSI
3.45 Bar |
100 PSI
6.9 Bar |
|
Length |
Width |
Height |
AHP10 |
6 |
34 |
69 |
42.3 |
1/2" NPT |
23 |
|
450 |
395 |
395 |
AHP26 |
14 |
90 |
181 |
16.0 |
1/2" NPT |
21 |
|
450 |
395 |
395 |
AHP36 |
17 |
122 |
250 |
12.3 |
1/2" NPT |
20 |
|
450 |
395 |
395 |
AHP58 |
28 |
200 |
400 |
7.6 |
1/2" NPT |
20 |
|
450 |
395 |
395 |
AHP107 |
62 |
373 |
738 |
4.0 |
1/2" NPT |
20 |
|
450 |
395 |
395 |
AHP187 |
97 |
638 |
1293 |
2.2 |
9/ 6"-18UNF |
20 |
|
450 |
395 |
395 |
AHP275 |
155 |
931 |
1897 |
1.6 |
9/ 6"-18UNF |
20 |
|
450 |
395 |
395 |
AHP425 |
345 |
1448 |
2931 |
1.0 |
9/ 6"-18UNF |
20 |
|
450 |
395 |
395 |
Hydraulic pressure |
Approximate rate of discharge (L/min) at air input pressure 100 PSI (7 Bar) |
PSI |
Bar |
AHP10 |
AHP26 |
AHP36 |
AHP58 |
AHP107 |
AHP187 |
AHP275 |
AHP425 |
0 |
0 |
23.10 |
8.80 |
6.00 |
3.56 |
1.97 |
1.15 |
0.72 |
0.43 |
500 |
35 |
12.00 |
5.85 |
4.39 |
3.05 |
1.50 |
1.05 |
0.68 |
0.40 |
1000 |
69 |
* |
4.72 |
3.80 |
2.51 |
1.28 |
1.00 |
0.65 |
0.38 |
1500 |
104 |
* |
3.90 |
3.34 |
2.38 |
1.25 |
0.90 |
0.60 |
0.36 |
2000 |
138 |
* |
3.00 |
3.00 |
2.25 |
1.21 |
0.78 |
0.55 |
0.34 |
2500 |
173 |
* |
1.21 |
2.56 |
2.05 |
1.18 |
0.75 |
0.50 |
0.33 |
3000 |
207 |
* |
* |
1.95 |
1.85 |
1.16 |
0.73 |
0.48 |
0.31 |
4000 |
276 |
* |
* |
* |
1.56 |
1.02 |
0.70 |
0.45 |
0.29 |
5000 |
345 |
* |
* |
* |
1.02 |
0.95 |
0.67 |
0.42 |
0.26 |
7500 |
517 |
* |
* |
* |
* |
0.76 |
0.60 |
0.40 |
0.25 |
10000 |
690 |
* |
* |
* |
* |
0.44 |
0.52 |
0.37 |
0.24 |
15000 |
1034 |
* |
* |
* |
* |
* |
0.39 |
0.33 |
0.21 |
20000 |
1379 |
* |
* |
* |
* |
* |
* |
0.30 |
0.20 |
25000 |
1724 |
* |
* |
* |
* |
* |
* |
0.21 |
0.16 |
30000 |
2069 |
* |
* |
* |
* |
* |
* |
* |
0.13 |
40000 |
2760 |
* |
* |
* |
* |
* |
* |
* |
0.05 |
* Pressure exceeds pump capacity.
|