Sanger Metal

S-502 - Closed Swage Sockets



  • Forged from special bar quality carbon steel, suitable for cold forming.
  • Swage Socket terminations have an efficiency rating of 100% based on the catalog strength of wire rope.
  • Hardness controlled by spheroidize annealing.
  • Stamp for identification after swaging without concern for fractures (as per directions in National Swaging Brochure).
  • Swage sockets incorporate a reduced machined area of the shank which is equivalent to the proper "After Swage" dimension. Before swaging, this provides for an obvious visual difference in the shank diameter. After swaging, a uniform shank diameter is created allowing for a QUIC-CHECK® and permanent visual inspection opportunity.
  • Designed to quickly determine whether the socket has been through the swaging operation and assist in field inspections, it does not eliminate the need to perform standard production inspections which include gauging for the proper "After Swage" dimensions or proof loading.
  • U.S. Patent 5,152,630 and foreign equivalents.

NOTE: S-502 Swage Sockets are recommended for use with 6 x 19 or 6 x 37, IPS or XIP (EIP), XXIP (EEIP), RRL, FC or IWRC wire rope. Before using any National Swage fitting with any other type lay, construction or grade of wire rope, it is recommended that the termination be destructive tested and documented to prove the adequacy of the assembly to be manufactured. In accordance with ANSI B30.9, all slings terminated with swage sockets shall be proof loaded.*

 

S-502

Closed Swage Sockets

S-502 Closed Socket Specyfications
Press / Die Data
S-502
Stock
No.
Rope
Size
(mm)*
Weight
Each
(kg)
Before Swage Dimensions
Max.
After
Swage
Dim.
(mm)
Die Description
Stock No. Side Load
A
B
C
D
E
F
H
L
500
1000
1500
Ton
5 x 7
1500
3000
Ton
6 x 12
1500
Ton
6 x 12
3000
Ton
6 x 12
1039325
6
0.15
109
12.7
35.1
19.1
6.85
54.0
12.7
89.0
11.7
1/4 Socket
1192845 - - -
1039343
8
0.34
138
19.6
41.1
22.4
8.65
81.0
17.0
114
18.0
5/16-3/8 Socket
1192863 - - -
1039361
9-10
0.33
138
19.6
41.1
22.4
10.4
81.0
17.0
114
18.0
5/16-3/8 Socket
1192863 - - -
1039389
11-12
0.64
176
24.9
51.0
26.9
12.2
108
21.8
146
23.1
7/16-1/2 Socket
1192881 - - -
1039405
13
0.64
176
24.9
51.0
26.9
14.0
108
21.8
146
23.1
7/16-1/2 Socket
1192881 - - -
1039423
14
1.32
220
31.8
60.5
31.8
15.5
135
28.7
184
29.5
9/16-5/8 Socket
1192907 - - -
1039441
16
1.29
220
31.8
60.5
31.8
17.0
135
28.7
184
29.5
9/16-5/8 Socket
1192907 - - -
1039469
18-20
2.27
261
39.4
73.0
36.6
20.3
162
33.3
219
36.1
3/4 Socket
1192925 - - -
1039487
22
3.08
303
43.2
79.0
42.9
23.9
189
38.1
257
39.4
7/8 Socket
1192943 - - -
1039502
24-26
4.72
344
50.5
92.0
52.5
26.9
216
44.5
292
45.7
1 Socket
1192961 - - -
1039520
28
6.72
382
57.0
102
58.5
30.2
243
51.0
324
52.0
1-1/8 Socket
1192989 - - -
1039548
32
9.78
430
64.5
114
65.0
33.8
270
57.0
365
58.5
1-1/4 Socket
1193005 - - -
1039566
34-36
12.9
473
71.0
127
65.0
36.8
297
57.0
400
65.0
1-3/8 Socket
1193023 - - -
1039584
38-40
17.3
511
78.0
140
71.5
40.1
324
63.5
432
71.5
1-1/2 Socket
1193041 1191267 1193355 1195192
1039600
44
23.1
598
86.0
159
90.5
47.2
378
76.0
508
77.5
1-3/4 Socket
1193069 1191276 1195367 1195209
1042589
48-52
40.5
702
100
184
96.5
53.5
432
82.5
584
90.5
2 Socket
1193087 1191294 1195379 1195218
* Maximum Proof Load shall not exceed 50% of XXIP rope catalog breaking strength.